Summary | Fixed bug + added support for getting usage from Sentinel LM/RMS |
Platform | Windows |
Category | bugfix |
Valid for | 4.9.x, 5.0.x, 5.1.x, 5.2.x, 5.3, 5.3.0.1 |
Requires | 1067 |
Server Required Patch/es | |
Supersedes | 1072 |
Superseded by | 1083 : Cancelled / Not hidden |
Affects | Client: License Analyzer |
Last Updated | September 30, 2009 |
Fixed bug when reading PACKAGES in FLEXlm license file. (When the package had only one component, additional non-existing non-sense components were also included.) Additionally, a new license type was defined, supporting Sentinel LM. This is done by parsing the output from the lsmon program included with Sentinel.
Added a parser in the LicPoll application that can report license usage of Sentinel LM by parsing the output of lsmon.exe. This patch is in the Alpha stage.
Unpack the zip file anywhere on the machine to patch. Run the InstallPatch.exe application. Once the patch has been installed, you may delete the unpacked patch directory. After you install this patch, you need to manually do the changes as mentioned below, if you want Sentinel LM support: 1. Use an xml editor, or a plain text editor to open the file licpoll.xml in the location [OpeniT-installdir]\Configuration\Components A.Scan down until you find the object named "Sentinel-sample". B.Replace the "Sentinel-sample" object name to your chosen product name. C.Set the value of "active" object to 'true' to activate this license type. D.Modify the value of "status-command" object to the location of the lsmon.exe. E.Set the server name of the SentinelLM to the value of the "arguments" object. 2. Run the Confbuilder.exe to update the configuration files. This executable can be found in the location [OpeniT-installdir]\bin NOTE: The patch must be installed by a user with administrator rights.
No corresponding Patches available.